{"id":4010,"date":"2018-11-26T05:16:01","date_gmt":"2018-11-26T05:16:01","guid":{"rendered":"http:\/\/www.adtechamm.com\/?p=4010"},"modified":"2018-11-26T05:16:01","modified_gmt":"2018-11-26T05:16:01","slug":"molten-aluminium-degassing-refining-machine","status":"publish","type":"post","link":"https:\/\/www.adtechamm.com\/es\/molten-aluminium-degassing-refining-machine\/","title":{"rendered":"An\u00e1lisis de los problemas de desgasificaci\u00f3n del aluminio"},"content":{"rendered":"<p><strong>An\u00e1lisis de los problemas de desgasificaci\u00f3n del aluminio<\/strong><\/p>\n<p>An\u00e1lisis de problemas de desgasificaci\u00f3n del aluminio: formaci\u00f3n de escoria en la tapa del dep\u00f3sito de desgasificaci\u00f3n<br \/>\n1. Principalmente porque el nivel actual del aluminio l\u00edquido est\u00e1 demasiado bajo con respecto a la tapa. La espuma salpic\u00f3 durante el proceso de refinado.<br \/>\n2. Para resolver el problema de la formaci\u00f3n de escoria, cambia la estructura de la caja y busca el rotor y la carcasa del calentador adecuados.<br \/>\n3. La parte superior del orificio de escoria no tiene tapa, lo que afecta a la estanqueidad. Se recomienda colocar una tapa.<br \/>\n4. El manguito del rotor presenta un holgura considerable, lo que afecta al sellado. Se recomienda utilizar un sellado de empaquetadura.<\/p>\n<p><img class=\"alignnone wp-image-4012\" src=\"http:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis.jpg\" alt=\"An\u00e1lisis de los problemas de desgasificaci\u00f3n del aluminio\" width=\"600\" height=\"800\" srcset=\"https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis.jpg 3120w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis-225x300.jpg 225w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis-768x1024.jpg 768w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis-600x800.jpg 600w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis-700x933.jpg 700w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><a href=\"http:\/\/www.adtechamm.com\/es\/2018\/04\/08\/aluminium-degassing-machine\/\">Desgasificaci\u00f3n del aluminio<\/a> An\u00e1lisis del problema: ignici\u00f3n instant\u00e1nea del hidr\u00f3geno durante el uso del equipo<br \/>\n1. Cuando la velocidad de rotaci\u00f3n es baja y el caudal de gas es elevado, el nivel del l\u00edquido fluct\u00faa considerablemente y aparecen burbujas grandes.<br \/>\n2. Tras el ajuste, el nivel de l\u00edquido se mantiene estable y el destello de hidr\u00f3geno se distribuye de manera uniforme.<\/p>\n<p><img class=\"alignnone size-full wp-image-4013\" src=\"http:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminum-Degassing-Problem-Analysis.jpg\" alt=\"An\u00e1lisis de los problemas de desgasificaci\u00f3n del aluminio\" width=\"582\" height=\"621\" srcset=\"https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminum-Degassing-Problem-Analysis.jpg 582w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminum-Degassing-Problem-Analysis-281x300.jpg 281w\" sizes=\"(max-width: 582px) 100vw, 582px\" \/><\/p>\n<p>An\u00e1lisis de los problemas de desgasificaci\u00f3n del aluminio: uso del rotor<br \/>\nEl rotor utiliza una foto de hace 10 meses en la que no se aprecia desgaste ni acumulaci\u00f3n de escoria.<\/p>\n<p><img class=\"alignnone wp-image-4014\" src=\"http:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/\u56fe\u72473.jpg\" alt=\"\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/\u56fe\u72473.jpg 1280w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/\u56fe\u72473-300x169.jpg 300w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/\u56fe\u72473-768x432.jpg 768w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/\u56fe\u72473-1024x576.jpg 1024w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/\u56fe\u72473-700x394.jpg 700w, https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/\u56fe\u72473-539x303.jpg 539w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Aluminium Degassing Problem Analysis Aluminium Degassing Problem Analysis -Degassing tank cover slagging 1.Mainly because the current structure of aluminum liquid is too low from the cover. The scum splashed up during refining. 2.To solve the problem of slagging, change the structure of the box and&#8230;<\/p>","protected":false},"author":1,"featured_media":4012,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[52],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Aluminium Degassing Problem Analysis - Sales@adtechamm.com<\/title>\n<meta name=\"description\" content=\"Aluminium Degassing Problem Analysis -Degassing tank cover slagging-Mainly because the current structure of aluminum liquid is too low from the cover.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.adtechamm.com\/es\/molten-aluminium-degassing-refining-machine\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aluminium Degassing Problem Analysis - Sales@adtechamm.com\" \/>\n<meta property=\"og:description\" content=\"Aluminium Degassing Problem Analysis -Degassing tank cover slagging-Mainly because the current structure of aluminum liquid is too low from the cover.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.adtechamm.com\/es\/molten-aluminium-degassing-refining-machine\/\" \/>\n<meta property=\"og:site_name\" content=\"Adtech China\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/avril.allen.3994\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/profile.php?id=100058838456679\" \/>\n<meta property=\"article:published_time\" content=\"2018-11-26T05:16:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3120\" \/>\n\t<meta property=\"og:image:height\" content=\"4160\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AdTech\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@AdTech_China\" \/>\n<meta name=\"twitter:site\" content=\"@AdTech_China\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"AdTech\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/\",\"url\":\"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/\",\"name\":\"Aluminium Degassing Problem Analysis - Sales@adtechamm.com\",\"isPartOf\":{\"@id\":\"https:\/\/www.adtechamm.com\/#website\"},\"datePublished\":\"2018-11-26T05:16:01+00:00\",\"dateModified\":\"2018-11-26T05:16:01+00:00\",\"author\":{\"@id\":\"https:\/\/www.adtechamm.com\/#\/schema\/person\/3e620479604c811a3f1f75bb70841291\"},\"description\":\"Aluminium Degassing Problem Analysis -Degassing tank cover slagging-Mainly because the current structure of aluminum liquid is too low from the cover.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/www.adtechamm.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aluminium Degassing Problem Analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.adtechamm.com\/#website\",\"url\":\"https:\/\/www.adtechamm.com\/\",\"name\":\"Adtech China\",\"description\":\"Alumina ceramic foam filter, aluminum degassing\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.adtechamm.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.adtechamm.com\/#\/schema\/person\/3e620479604c811a3f1f75bb70841291\",\"name\":\"AdTech\",\"description\":\"Alumina ceramic foam filter &amp; degassing unit\",\"sameAs\":[\"https:\/\/www.adtechamm.com\/\",\"https:\/\/www.facebook.com\/profile.php?id=100058838456679\",\"https:\/\/www.linkedin.com\/in\/--618200221\/\",\"https:\/\/youtube.com\/@adtechamm2577\",\"https:\/\/www.tumblr.com\/adtechmetallurgicalmaterials\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"An\u00e1lisis de problemas de desgasificaci\u00f3n del aluminio - Sales@adtechamm.com","description":"An\u00e1lisis del problema de desgasificaci\u00f3n del aluminio: formaci\u00f3n de escoria en la tapa del tanque de desgasificaci\u00f3n. Se debe principalmente a que la altura actual del aluminio l\u00edquido est\u00e1 demasiado por debajo de la tapa.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.adtechamm.com\/es\/molten-aluminium-degassing-refining-machine\/","og_locale":"es_ES","og_type":"article","og_title":"Aluminium Degassing Problem Analysis - Sales@adtechamm.com","og_description":"Aluminium Degassing Problem Analysis -Degassing tank cover slagging-Mainly because the current structure of aluminum liquid is too low from the cover.","og_url":"https:\/\/www.adtechamm.com\/es\/molten-aluminium-degassing-refining-machine\/","og_site_name":"Adtech China","article_publisher":"https:\/\/www.facebook.com\/avril.allen.3994","article_author":"https:\/\/www.facebook.com\/profile.php?id=100058838456679","article_published_time":"2018-11-26T05:16:01+00:00","og_image":[{"width":3120,"height":4160,"url":"https:\/\/www.adtechamm.com\/wp-content\/uploads\/2018\/11\/Aluminium-Degassing-Problem-Analysis.jpg","type":"image\/jpeg"}],"author":"AdTech","twitter_card":"summary_large_image","twitter_creator":"@AdTech_China","twitter_site":"@AdTech_China","twitter_misc":{"Escrito por":"AdTech","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/","url":"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/","name":"An\u00e1lisis de problemas de desgasificaci\u00f3n del aluminio - Sales@adtechamm.com","isPartOf":{"@id":"https:\/\/www.adtechamm.com\/#website"},"datePublished":"2018-11-26T05:16:01+00:00","dateModified":"2018-11-26T05:16:01+00:00","author":{"@id":"https:\/\/www.adtechamm.com\/#\/schema\/person\/3e620479604c811a3f1f75bb70841291"},"description":"An\u00e1lisis del problema de desgasificaci\u00f3n del aluminio: formaci\u00f3n de escoria en la tapa del tanque de desgasificaci\u00f3n. Se debe principalmente a que la altura actual del aluminio l\u00edquido est\u00e1 demasiado por debajo de la tapa.","breadcrumb":{"@id":"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.adtechamm.com\/molten-aluminium-degassing-refining-machine\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.adtechamm.com\/"},{"@type":"ListItem","position":2,"name":"Aluminium Degassing Problem Analysis"}]},{"@type":"WebSite","@id":"https:\/\/www.adtechamm.com\/#website","url":"https:\/\/www.adtechamm.com\/","name":"Adtech China","description":"Filtro de espuma cer\u00e1mica de al\u00famina, desgasificaci\u00f3n del aluminio","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.adtechamm.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.adtechamm.com\/#\/schema\/person\/3e620479604c811a3f1f75bb70841291","name":"AdTech","description":"Filtro de espuma cer\u00e1mica de al\u00famina y unidad de desgasificaci\u00f3n","sameAs":["https:\/\/www.adtechamm.com\/","https:\/\/www.facebook.com\/profile.php?id=100058838456679","https:\/\/www.linkedin.com\/in\/--618200221\/","https:\/\/youtube.com\/@adtechamm2577","https:\/\/www.tumblr.com\/adtechmetallurgicalmaterials"]}]}},"_links":{"self":[{"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/posts\/4010"}],"collection":[{"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/comments?post=4010"}],"version-history":[{"count":2,"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/posts\/4010\/revisions"}],"predecessor-version":[{"id":4015,"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/posts\/4010\/revisions\/4015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/media\/4012"}],"wp:attachment":[{"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/media?parent=4010"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/categories?post=4010"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.adtechamm.com\/es\/wp-json\/wp\/v2\/tags?post=4010"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}